Making Network Connections

4-6

4

Connectivity Rules

When adding hubs (repeaters) to your network, please follow the connectivity rules
listed in the manuals for these products. However, note that because switches break
up the path for connected devices into separate collision domains, you should not
include the switch or connected cabling in your calculations for cascade length
involving other devices.

1000BASE-T Cable Requirements

All Category 5 UTP cables that are used for 100BASE-TX connections should also
work for 1000BASE-T, providing that all four wire pairs are connected. However, it is
recommended that for all critical connections, or any new cable installations,
Category 5e (enhanced Category 5) or Category 6 cable should be used. The
Category 5e specification includes test parameters that are only recommendations
for Category 5. Therefore, the first step in preparing existing Category 5 cabling for
running 1000BASE-T is a simple test of the cable installation to be sure that it
complies with the IEEE 802.3-2005 standards.

1000 Mbps Gigabit Ethernet Collision Domain

Table 4-1 Maximum 1000BASE-T Gigabit Ethernet Cable Length

Cable Type

Maximum Cable Length

Connector

Category 5, 5e, 6 100-ohm UTP or STP

100 m (328 ft)

RJ-45

Table 4-2 Maximum 1000BASE-SX Fiber Optic Cable Length

Fiber Diameter

Fiber Bandwidth

Cable Length Range

Connector

62.5/125 micron multimode

fiber (MMF)

160 MHz/km

2-220 m (7-722 ft)

LC

200 MHz/km

2-275 m (7-902 ft)

LC

50/125 micron multimode fiber

(MMF)

400 MHz/km

2-500 m (7-1641 ft)

LC

500 MHz/km

2-550 m (7-1805 ft)

LC

Table 4-3 Maximum 1000BASE-LX Fiber Optic Cable Length

Fiber Diameter

Fiber Bandwidth

Cable Length Range

Connector

9/125 micron single-mode fiber N/A

2 m - 5 km

(7 ft - 3.2 miles)

LC

Table 4-4 Maximum 1000BASE-LH Fiber Optic Cable Length

Fiber Diameter

Fiber Bandwidth

Cable Length Range

Connector

9/125 micron single-mode fiber N/A

2 m - 70 km

(7 feet - 43 miles)

LC