Crossover wiring, 1000base-t pin assignments, Table b-2 – Accton Technology Edge-corE 24-Port Gigabit Ethernet Lite Switch ES4324 User Manual

Page 47: 1000base-t mdi and mdi-x port pinouts, Figure b-3

Advertising
background image

Twisted-Pair Cable and Pin Assignments

B-3

B

Crossover Wiring

If the twisted-pair cable is to join two ports and either both ports are labeled with an
“X” (indicating MDI-X) or neither port is labeled with an “X” (which indicates MDI), a
crossover must be implemented in the wiring. (When auto-negotiation is enabled for
any RJ-45 port on the switch, you can use either straight-through or crossover cable
to connect to any device type.)

You must connect all four wire pairs as shown in the following diagram to support
Gigabit Ethernet connections.

Figure B-3 Crossover Wiring

1000BASE-T Pin Assignments

All 1000BASE-T ports support automatic MDI/MDI-X operation, so you can use
straight-through cables for all network connections to PCs or servers, or to other
switches or hubs.

The table below shows the 1000BASE-T MDI and MDI-X port pinouts. These ports
require that all four pairs of wires be connected. Note that for 1000BASE-T
operation, all four pairs of wires are used for both transmit and receive.

Use 100-ohm Category 5, 5e or 6 unshielded twisted-pair (UTP) or shielded
twisted-pair (STP) cable for 1000BASE-T connections. Also be sure that the length
of any twisted-pair connection does not exceed 100 meters (328 feet).

Table B-2 1000BASE-T MDI and MDI-X Port Pinouts

Pin

MDI Signal Name

MDI-X Signal Name

1

Bi-directional Data One Plus (BI_D1+)

Bi-directional Data Two Plus (BI_D2+)

2

Bi-directional Data One Minus (BI_D1-)

Bi-directional Data Two Minus (BI_D2-)

3

Bi-directional Data Two Plus (BI_D2+)

Bi-directional Data One Plus (BI_D1+)

White/Orange Stripe

Orange

White/Green Stripe

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

EIA/TIA 568B RJ-45 Wiring Standard

10/100BASE-TX Crossover Cable

End A

End B

Green

Blue

White/Blue Stripe

Brown

White/Brown Stripe

Advertising