Parameter Settings

These parameter settings are loaded into the controllers at the factory and should
not need adjustment. Please contact the factory before making any changes to the
parameter settings and for instructions on getting into the programming mode.

A.

Display

Actual Setting

Setting

Command/ Procedure

CBLE

15

15

Default cable diameter.

POSN

0-2500

0-2500

Drum position reading of the

potentiometer. It is used to locate the

drum loading and transport position.

B1

55

Bias transport to engine—to set the drum

sensitivity moving toward the engine.

B2

55

Bias load to server—to set the drum

sensitivity moving toward the arms.

B3

55

Bias server load—to set the motor

sensitivity rotating the arms.

B4

0

0

Bias free wheel—keep it at zero.

LENG

1360

1360

Drum length measuring between the two

flanges—always set it at 1360.

SCNT

336

Drum position for loading.

ECNT

2026

Drum position for transporting.

GAIN

5

5

D1

100

100

Minimum drag.

D2

60

60

Maximum drag.

SLAG

0

0

Pulses on server before spool

move—always set it at zero.

7PNH

140

146

The speed of the drum moving to

transport position.

LOAD

140

141

The speed of the drum moving to

load position.

APPENDIX