Counter clear, Information with error messages, Information for filter indicator – Sharp R-22AT User Manual

Page 14

Advertising
background image

13

Each number of times can be cleared.

COUNTER CLEAR

* Suppose you want to clear the times of memory 1.

Step

Action

1

Select check mode.

Note: 1. To clear times of manual cooking, press MANUAL/REPEAT pad at Step 2 instead of NUMBER pad.

To clear times of EXPRESS DEFROST cooking, press EXPRESS DEFROST pad at Step 2
instead of NUMBER pad.

2. To clear total using times, miss out Step 2.

INFORMATION WITH ERROR MESSAGES

EE1 EE2 EE3 EE6 EE8 EE0
EE10 EE16

EE7

EE9

EE17

Please contact your dealer or an authorized service agent because the
oven is malfunctioning.

Exhaust air temperature is too high. Check that nothing is blocking the
vent openings and air intake openings or that room temperature is too
hot or that oven cavity is empty during operation. Correct, press STOP/
CLEAR pad and try again after a few minutes.

Cooking time exceeds the max. time. Press STOP/CLEAR pad and
programme again.

Magnetron temperture is too high. Press STOP/CLEAR pad and try again
after a few minutes.

ERROR MESSAGES

If ERROR messages are displayed, follow the instructions below.

1. Clean the air intake filter when the FILTER indicator ligfts up. See page 28. The FILTER indicator will light

up when the oven has been operated for about 200 hours in total.

2. To cancel FILTER indicator press the START pad. The oven will start to count the operation time

automatically again when the FILTER indicator is cancelled.

INFORMATION FOR FILTER INDICATOR

Display

CHECK

2

Press NUMBER pad

1

.

NUMBER

CHECK

(Total times used)

(Times memory 1 was used)

Press SET pad.

3

4

Cancel check mode.

NUMBER

CHECK

Press pad

X 2

1

SET

CHECK

CHECK

Advertising