Bay Technical Associates DS72 User Manual

Page 21

Advertising
background image

DS72 HOST MODULE OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

16

Header is......................... Disabled
Enable? (Y/N, CR for no change):

Type “Y” followed by <cr> if you want to enable Header status. Type “N”
followed by <cr> if you want to disable Header. Enter <cr> for no change.

Password

To change Password or Enable/Disable Password upon login, select #2,
“Password,” from the selection menu, followed by <cr>. Default Password
is BTA, disabled.
The DS72 module responds:

Change Password....................1
Enable/Disable.....................2
Exit...............................X, CR

To change the current password, select #1, “Change Password,” followed by
<cr>. The DS72 module responds:

Enter New Password (1 - 8 char., CR to end):

Enter the new password up to 8 ASCII characters followed by <cr>. The
DS72 module stores the new password in non-volatile memory and returns
to the selection menu.

To toggle Password status, select #2, “Enable/Disable,” followed by <cr>.
The DS72 module displays the current status and asks if you want to enable:

Password is ......................... Disabled
Enable? (Y/N, CR for no change):

Enter “Y” followed by <cr> if you want to enable Password. Type “N”
followed by <cr> if you want to disable Password. Enter <cr> for no
change.

Menu Enable/Disable Menu upon login. Default menu is enabled. If disabled,the

following header appears upon login without the main menu:

Data Switch Series - F.1.00
Bay Technical Associates
Unit ID: BAYTECH DS72

Port Select Code: $BT
Attention Character: ;

NOTE: To invoke the main menu when disabled, enter the attention character five times (;;;;;).