DS72 HOST MODULE OWNER’S MANUAL

INTRODUCTION TO THE DS72 HOST MODULE

1

INTRODUCTION TO THE DS72 NETWORK INTERFACE
MODULE

The DS72 network interface module is a primary user interface for use with the BayTech DS-Series and
DS-RPC units. The DS72 allows network users operating on a device using a TCP/IP stack with an
ethernet connection, to access the main DS units, serial I/O modules, and (in the case of the DS-RPC)
remote power switches. It also allows remote access via external modem to the serial port. This makes the
DS72 an extremely versatile module, covering most applications.

PROGRAMMABLE FEATURES OF THE DS72

Highlighted features indicate items most often programmed

FEATURE

DESCRIPTION

ACTION

PAGE
NO.

DS72

N

ETWORK

I

NTERFACE

M

ODULE

Serial Port
Configuration

Sets serial port speed of the DS72 Default = 9600, 8, 1, N,
Xon/Xoff Disabled

Enter baud rate, data bits,
stop bits, parity, and
Xon/Xoff

11

Port Device
Name

Uniquely identifies the port (or device connected to the port).
Default = Host EIA-232

Enter the device name

12

Port Select Code

ASCII character string used to select a port or module.
Default = $BT

Enter Port Select Code

13

Attention
Character

A character sent in sequence five times to invoke the main
menu. Default = ;

Enter Attention Character

14

Disconnect Time
Guard

Provides reliable binary data transmission. Default =
Disabled

Enable/Disable
Disconnect Time Guard

14

Port ID Echo

Echoes the module number and port number when you
connect to the port.
Default = Disabled

Enable/Disable Connect
Port ID Echo

14

Header

Unit information that appears upon login
Default = DS72

Enable/Disable Header

15

Password

Password protection for telnet and EIA-232 connections.
Default = Disabled

Enable/ Disable, and
Program Password

16

Menu

Provides a menu interface for device selection, and
configuration.
Default = Enabled

Enable/Disable Menu

16

Auto Connect
Port

Allows automatic connection to a specified port upon Telnet
or EIA-232 connection.
Default = Disabled

Enable,/Disable, and
Program Auto Connect
Port.

17

IP Address

IP Address for the DS72 to access the network.
Default = 0.0.0.0

Enter the IP Address in
dotted decimal format
0.0.0.0

18

Subnet Mask

Consists of four bytes, each byte ranging from 0 to 255.
Default = 0.0.0.0

Enter the Subnet Mask in
dotted decimal format
0.0.0.0

19

Gateway

Consists of four bytes, each byte ranging from 0 to 255.
Default = 0.0.0.0

Enter the Gateway in
dotted decimal format.
0.0.0.0

19