Gas connection

d

WARNING

d

Explosion hazard!

Use a new AGA or CSA approved

gas supply line.

Install a shutĆoff valve.

Securely tighten all gas

connections.

Have a qualified person make sure

gas pressure does not exceed

14 in. W.C./ 3.49 kPa/ 0.506 psig.

(Natural and Propane Gas).

Example of a qualified person

include:

-

licensed heating personnel,

-

authorized gas supplier personnel,

-

authorized service personnel.

Failure to do can result in explosion

or fire.

Risk of death or injury!

All gas line connections must be teĆ

sted for leaks prior to appliance

operation. Apply soapy water to gas

line connections and check for forĆ

mation of new bubbles. Bubbles inĆ

dicate leak!

When installing the gas supply to the

gas dryer inlet pipe, do not exceed 310

lbf in (35 Nm).

d

WARNING

d

Never use an open flame to test for

gas leaks.

Gas type

This gas dryer when equipped for use

with NATURAL GAS, will employ an

orifice size 46 and have a gas outlet

pressure of 3.5 in. W.C. This gas dryer

when equipped for use with PROPANE

GAS, will employ an orifice size of 1.21

mm, and have a gas outlet pressure of

11 in. W.C.
Your dryer must have the correct valve

for the type of gas in your home. Valve

information is located on the rating

plate behind the door below the drum.
If the ratingĆplate information does not

agree with the type of gas available,

contact your dealer or our customer

service team (see page 21).

Gas supply line

1

/

2

" I.D. pipe is recommended.

3

/

8

" approved tubing is acceptable for

lengths under 20 ft (6.1 m) if local

codes and gas supplier permit.
Must include

1

/

8

" NPT plugged

tapping, immediately upstream of the

gas connection.
A shut off valve must be included:
-

USA:

An individual manual shutĆoff valve

must be installed within 6 ft (1.8 m)

of the dryer in accordance with the

National Fuel Gas Code, ANSI

Z223.1.

-

Canada:

An individual manual shutĆoff valve

must be installed in accordance

with the B149, Installation Codes,

CAN/CSA B149.1 and CAN/CSA

B149.2. It is recommended that an

individual manual shutĆoff valve be

installed within 6 ft (1.8 m) of the

dryer.

1

1111

2

3

4

5

1 ć

1

/

2

" NPT gas supply line

2 ć Gas shutĆoff valve
3 ć

1

/

8

" NPT plugged tapping

4 ć

3

/

8

" pipe to flare adapter fitting

5 ć

3

/

8

" flexible gas connector (to the dryer)

The shutĆoff valve should be easy to

reach for opening and closing.

Note:

The dryer must be checked for proper

operation whenever the gas

connections have been broken.

Dryer gas pipe

The gas pipe that comes out through

the rear of the dryer has a

3

/

8

" male

pipe thread.

Connection of the dryer

d

CAUTION

Connection must be made by

a qualified technician.

The dryer must be disconnected

from the gas supply piping system

during testing pressure.

When using for the first time make

sure that there is no air in the piping

system.

d

WARNING

d

Do not use copper pipes and tubing

if connected to natural gas.

The connection may be different,

according to the supply line type, size

and location.
If local codes permit, use a flexible

stainless steel connector (Design

certified by the America Gas

Association or CSA International)

to connect the dryer.

1

2

To reduce the distance between body

sheet and wall install a

3

/

8

" elbow on

the gas pipe of the dryer.
1 ć gas pipe (

3

/

8

" male pipe thread)

2 ć

3

/

8

" elbow

Exhaust air connection

d

WARNING

d

1. To reduce the risk of fire, this dryer

MUST BE EXHAUSTED

OUTDOORS.

2. To reduce the risk of fire, do not

use ductwork longer than

recommended.

3. DO NOT use a plastic or

nonĆmetal duct with this dryer.

4. DO NOT use a duct smaller than 4

inches in diameter.

5. DO NOT use exhaust hoods with

magnetic latches.

6. DO NOT exhaust the dryer into a

chimney, furnace cold air duct,

attic, crawl space, or any other

ductwork used for venting.

7. DO NOT install a flexible duct in an

enclosed wall, ceiling or floor.

8. DO NOT crush or kink the duct.
9. Do clean and inspect the exhaust

system on a regular basis; at least

once a year.

10. The exhaust duct must terminate

in a manner to prevent back drafts

or entry of birds or other wildlife.

The Bosch dryer must be vented

outdoors. To prevent buildĆup of

moisture and accumulation of lint

indoors, as well as to maintain

maximum drying efficiency, it is

recommended that the dryer is vented

outdoors.

Exhaust air outlet on the dryer

The dryer is delivered with an exhaust

air outlet on the rear of the appliance.
To take account of the spatial

requirements and an existing exhaust

air system, the following connection

options are possible for the exhaust air

outlet:
-

on right side of the appliance,

-

on the underside of the appliance.

Advertising