Baldor PC32RI User Manual

Page 19

Advertising
background image

Section 4

Operation

Operation 4-1

MN2403

Operator Control Panel

The Operator Control Panel is shown in Figure 4-1.

Figure 4-1 Operator Control Panel

STOP

ON

CHOKE

+

− +

Engine

Switch

Auto

P−Save LED

Multi Monitor Display

Oil Level

Lamp

Units LED’s

Key

Switch

Units
Select
Switch

Auto Power Save Switch

NEMA 5−20R

NEMA L530R

Ground

Terminal

(−) Battery Charger

Connection

DC

Breaker

STOP

ON

START

BATTERY CHARGE ONLY

DC 12V − 8.3A

~ AC OUTPUT

(+) Battery Charger

Connection

Multi Monitor Display

A five digit display for messages or display of Hours, Volts or Hertz.

Overload Display

“O_LOD” is displayed on the Multi Monitor display when generator is running and an

overload condition exists. To reset, Stop the generator and Start the generator again to

resume operation.

Units LED’s

When Units Select Switch is set to Hours, Units Hours LED is ON and

operating hours is displayed on Multi Monitor Display.

When Units Select Switch is set to V, Units V LED is ON and

Generator Output Volts is displayed on Multi Monitor Display.

When Units Select Switch is set to Hz, Units Hz LED is ON and

Generator Output Frequency is displayed on Multi Monitor Display.

Units Select Switch

Pressing Switch changes display modes from Hours, Volts and Hz.

Oil Level Lamp

Lamp is on when engine oil level is less than a predetermined level. When the lamp

turns ON, the engine will stop automatically. If Oil Lamp is ON, replenish the engine oil

level and restart the engine.

Auto Power Save Switch Press to select Power Save Mode, (Auto P−Save LED is ON) and generator speed

changes for the applied load. Output voltage and frequency remain constant even at

engine idle speed.

Press again to deselect Power Save mode and generator runs at full speed and

produces full power. Use this mode (Auto P−Save LED is OFF) for DC power.

Auto P−Save LED

OFF when generator runs at full speed and produces full power.

ON when generator is in Power Save Mode (Adjustable Speed).

Engine Switch

Stop

In this position, the engine is stopped and fuel supply line is closed.

Run

Allows the engine to start and run during normal operation.

Choke

Allows cold weather starting, place the Engine Switch in the Run position

after engine is started.

Key Switch

Stop

In this position, the engine is stopped.

ON

Engine run position after starting.

Start

Engine start position, engages engine starter to crank the engine.

Advertising
This manual is related to the following products: