Option battery switch off on – Bogen LUMDMU User Manual

Page 8

Advertising
background image

5

Set the MDMU options on the DIP switch. Refer to
the table below.

NOTE: Switches 1, 2, and 3
sets the number of messages in
a single queue sequence. The
timing between those
messages is set by switches 4,
5, and 6. Switch 7 sets the
total possible number of
messages for the unit. Switch
8 is always in the ON position.

REM

OPTION

BATTERY

SWITCH

OFF ON

Figure 6 Set MDMU Options on DIP Switch

Table 1. DIP Switch Setting Definitions

MAX. No. of
MESSAGES IN
SEQUENCE:

SET
SWITCH
# 1 TO

SET
SWITCH
# 2 TO

SET
SWITCH
# 3 TO

SET
SWITCH
# 4 TO

SET
SWITCH
# 5 TO

SET
SWITCH
# 6 TO

SET
SWITCH
# 7 TO

1

ON

ON

ON

2

OFF

ON

ON

3

ON

OFF

ON

4

OFF

OFF

ON

5

ON

ON

OFF

6

OFF

ON

OFF

7

ON

OFF

OFF

8

OFF

OFF

OFF

DEFAULT DELAY BETWEEN MESSAGES:

0:05

ON

ON

ON

0:10

OFF

ON

ON

0:30

ON

OFF

ON

1:00

OFF

OFF

ON

5:00

ON

ON

OFF

15:00

OFF

ON

OFF

30:00

OFF

OFF

OFF

NUMBER OF MESSAGES AVAILABLE:

1 TO 9

ON

01 TO 99

OFF

5

Advertising