14

Switching the appliance on and off

Switching the appliance on

Press the On/Off button until the temperature display

lights up.

Switching the appliance off

Keep the On/Off button pressed for approx. 3 seconds so that

the temperature display goes out.

Operating and control elements

The electronic control panel has the "touch capacitance tech-

nology".

Any function can be activated by touching the corresponding icon.

The exact contact point is

between the symbol and its label

1

Upper compartment temperature display

2

Lower compartment temperature display

3

Upper compartment temperature setting buttons

4

Lower compartment temperature setting buttons

5

On/Off button (switching the appliance on and off)

6

Audible warning On/Off button

7

Fan switch

8

Interior light On/Off button

Symbols in the display

Alarm (symbol flashes if the temperature inside the appli-

ance is too high or too low)

Demo mode is activated
Setup mode is activated (activating the child lock and

adjusting the display brightness

The interior fan runs constantly

Child lock is activated

The interior light is switched on constantly

Electrical connection

Only operate the appliance with alternating current (AC).

The permissible voltage and frequency are indicated on the type

plate. The position of the type plate is shown in the section entitled

Description of the appliance.

The socket must be properly earthed and protected by a fuse.

The tripping current of the fuse must be between 10 A and 16 A.

The socket must not be situated behind the appli-

ance and must be easily accessible.

Do not connect the appliance using an exten-

sion cable or extension socket.
Do not use stand-alone inverters (conversion

of direct current to alternating/three-phase

current) or energy-saving plugs. Risk of dam-

age to the electronic control system!

Setting up

• Avoid positioning the appliance in direct sunlight or near cookers,

radiators and similar sources of heat.

• The floor on which the appliance stands should be horizontal

and level.Compensate for uneven floors with the adjustable feet.

Do not cover ventilation openings

or grille.

• Standard EN 378 specifies that the room in

which you install your appliance must have a

volume of 1 m

3

per 8 g of R 600a refrigerant

used in the appliance, so as to avoid the forma-

tion of inflammable gas/air mixtures in the room

where the appliance is located in the event of

a leak in the refrigerant circuit. The quantity of

refrigerant used in your appliance is indicated

on the type plate on the inside of the appliance.

• Always install the appliance directly against

the wall.

• Place the appliance in its final position

at the place of installation.

Extend the adjustable foot at the bottom

hinge bracket until it rests on the floor

and then make a further 90° turn.

Appliance dimensions