BevLes CA34-CV9 User Manual

Page 16

Advertising
background image

Figure 43

Figure 44

Figure 45

Figure 42

Figure 41

Figure 40

6-1k. Replacing the fan blower motor assembly.

**NOTE:

**NOTE:

**NOTE:

Required: Medium (6") flathead screwdriver, Medium (6”) phillips

screwdriver, Crescent or standard wrench, Wiring markers (color or

number codes), Electrical tape

1. Remove top mounted heating module as found in section 6-1a.

2. Remove the fan blower motor assembly cover (on the left side

of module as you are facing the front panel) by removing the two

front and two rear screws with a medium (6”) flathead

screwdriver. (Fig. 40)

3. Pry off fan blower housing cover (with a flathead screwdriver, if

necessary). Without disconnecting wires, set cover on a clean

work area. (Fig. 41)

4. Mark all the wires connected to the fan blower motor(s) with a

color code or number to make proper re-connection easy. (Fig.

42)

5. Remove wire nuts and set cover aside.

6. For CA70 units, remove the two screws securing the clips that

attach the copper thermostat probe to the fan blower. Use a

medium flathead screwdriver. Free the copper probe and

carefully set out of the way. (Fig. 43)

DO NOT kink or bend copper tubing or probe.

Remove four screws (two at each end) that hold the fan blower

motor bracket in place. Use a medium flathead screwdriver.

7. For CA43 units, remove four screws (two at each end) that hold

the fan blower motor bracket in place. Use a medium flathead

screwdriver. Gently lift bracket to expose mounting clips for the

copper thermostat probe. Remove the two screws securing the

clips holding the copper thermostat probe with medium flathead

screwdriver. Free copper probe and carefully set out of the way.

(Figs. 44 &45)

DO NOT kink or bend copper tubing or probe.

8. Remove fan blower motor bracket with fan blower motor(s) still

attached and place entire assembly on a clean work space.

(Fig. 46)

9. Remove fan blower motor(s) from mounting bracket by

removing four securing screws with a medium (6”) flathead

screwdriver.

10. Mount new motor(s) in same position with the four phillips

screws.

All replacement motors will have two drilled holes in

the blower portion - these are irrelevant unless you are

replacing the front motor on a CA70 and will not affect

performance in any application.

11. Replace the fan blower motor bracket in heating module with

large flange up. (Fig. 46) .