4. If you are unable to locate the problem in the table or if the solutions listed don't work, please call the

BEVLES manufacturing facilities for assistance at (800) 441-1601. You will need to provide the

factory personnel with the following information:

1. The product model and serial numbers.

2. The specific nature of the problem.

In some cases it will be beneficial to also have the actual operator of the equipment available to answer

questions.

1. Unit will not heat.

2. Unit not reaching

or holding desired

Temperature uniformly.

3. Unit overheating.

4. Fan blowers not

operating.

5. Cabinet steamy and

too humid.

6. Cabinet too dry.

Power switch not in on position.

Loose or unplugged power cord.

Thermostat on wrong setting.

Faulty thermostat (not switching heating

element on when below set temperature).

Faulty internal wiring.

Faulty heating element (not getting hot).

Hi-temperature safety thermostat on.

Doors left open or ajar.

Thermostat on wrong setting.

Faulty thermostat (not switching heating

element on when below set temperature).

Faulty internal wiring.

Top mounted heating module seal

(gasket) torn or worn.

Faulty heater fan blower (no air

circulating).

Faulty thermostat (not switching heating

element off when above set temperature).

Power switch not in on position.

Loose or unplugged power cord.

Faulty heater fan blower.

Faulty internal wiring.

Too much humidity in air flow.

Holding temperature not high enough.

Holding product too long in cabinet.

Water pan dry.

Not enough humidity in air flow.

Holding temperature too high.

Place the power switch in the ON

position.

Plug power cord into proper

electrical outlet.

Set thermostat to correct

temperature.

Replace thermostat per section 6-

1i or j.

Check connections for heating

module components per

sections 6-11.

Replace heating element per

section 6-11.

Check for failure of heating element

and/or thermostat not shutting

down.

Close doors firmly and keep closed

except. when loading or unloading

product.

Set thermostat to correct

temperature.

Replace thermostat per section

6-1i or j.

Check connections for heating

module components per section 6-

11

Replace gasket per section 6-1 m.

Replace fan blower motor per

section 6-1k.

Replace thermostat per section 6-1i

or j.

Place the power switch in the on

position.

Plug power cord into proper

electrical outlet.

Replace fan blower motor per

section 6-1k.

Check connections for heating

module components per sections

6-11.

Adjust baffles per section 3-2.

Adjust thermostat to a higher

temperature level.

Minimize holding time.

Fill 3/4 full with water.

Adjust baffles per section 3-2.

Adjust thermostat to a lower

temperature (never below 140°F).

5-2 TROUBLESHOOTING TABLE

Problem

Possible Cause

Solution