4.7 I

NSTALLING

D

UAL

E

XTERIOR

H

OOD

*

(HEPA 2000, HF 2.0, HEPA 3000, HF 3.0

AND

HEPA 4000

UNITS ONLY

)

4.7.1 A

SSEMBLING

D

UAL

E

XTERIOR

H

OOD

Exterior dual hood is coming in separate
parts. Using 2 #8 x 3/4” screws, assemble the
top metal screen and the plastic grille to the
dual exterior hood. Then, slide the bottom
metal screen to the dual exterior hood. See
illustration beside.

*Patent pending

4.7.2 L

OCATING THE

D

UAL

E

XTERIOR

H

OOD

The dual exterior hood must be installed at a minimum
distance of 18 inches (457 mm) from the ground.
See illustration beside.

4.7.3 C

ONNECTING

T

ANDEM

®

TRANSITION TO THE

D

UAL EXTERIOR

H

OOD

1. Using a jig saw, cut a 6’’ diameter

hole in the exterior wall and
insert the Tandem® transition
through this hole.

1) EXHAUST AIR TO OUTSIDE duct

- 25 -

VO0024

WARNING

Make sure this hood is at least 3 feet (0.9 m) away from any of the following:

• High efficiency furnace vent.
• Gas meter exhaust, gas barbecue-grill.
• Any exhaust from a combustion source.
• Garbage bin and any other source of contamination.

0

!

VD0083

18''

(457 mm)

VD0084

1

CAUTION

The Tandem® transition must be inserted in such a way that the

EXHAUST

AIR TO OUTSIDE

duct will be located on the top.

4. INSTALL THE UNIT

(CONT’D)