Controls – Broan HEPA 3000 User Manual

Page 29

Advertising
background image

5.4 I

NSTALLATION OF THE

O

PTIONAL

W

ALL

C

ONTROLS

(C

ONTROLS

C12 / CM

AND

C34 / CMR)

1.Determine the more convenient location for the control.

2.Remove the cover plate control (1). If you prefer to

have your optional main control mounted on an
approved outlet box or an approved mounting bracket
(not included), discard the backplate (2).

3. Take one end of the cable and pass it through the wall control backplate (or outlet

box or mounting bracket).

4. Splice back this end of the cable to access to the 4 wires. Remove the insulated

sleeve of each wire ends. Make a loop with each bare end wire to hook them
to their corresponding screw. Connect YELLOW wire to ‘’Y’’screw, RED wire to

‘’R’’screw, GREEN to ‘’G’’screw and BLACK to ‘’B’’screw. See illustration below.

CAUTION

Never install more than one optional wall control per unit.

WARNING

To avoid risk of electrical shocks, never install another wire in the same
electrical box than the one for the optional wall control.

0

!

WARNING

Always disconnect the unit before making any connections. Failure in
disconnecting power could result in electrical shock or damage of the wall
control or electronic module inside the unit.

0

!

- 29 -

5. CONTROLS

(CONT’D)

1

2

BLACK

wire

YELLOW

wire

GREEN

wire

RED

wire

WARNING

Make sure that the wires don’t short circuit between themselves or by
touching any other components on the wall control.

!

Advertising