5. Pass the other end of the cable through the wall. Reinstall the cover plate.Using

wall anchors (not included) and provided screws, mount the wall control on the

wall. See illustrations below.

1) Wall anchors

4) Control 1) Outlet box

3) Control

2) Control cable

5) Screws 2) Control cable

4) Screws

3) Control backplate

6. Route the cable to the unit.

7. Remove the front 8’’ oval port (A) and the front panel (B) of the unit by unscrewing

their retaining screws.

CAUTION

Keep control low voltage wiring at least 1 foot (305 mm) away from motors,
lightning ballast, light dimming circuit and power distribution panel. Do not
route control wiring along with house power wiring. Avoid poor wiring
connections. Failure to follow these practices can introduce electrical
interference, which can cause erratic control operations.