3 panel pba and sensor problem, Rev. 2.01 – BIXOLON 352plusA User Manual

Page 53

Advertising
background image

Rev. 2.01

- 53 -

SRP-350/352plusA&C

7-3 Panel PBA and Sensor Problem

Feed S/W

Ok?

Cover Open

S/W Ok?

End

1. Check the Feed S/W Signal on Main PBA

2. Check the Harness

3. Check the related Circuit ,Pattern & Component

1. Check the Cover S/W Signal on Main PBA

2. Check the Harness

3. Check the related Circuit ,Pattern & Component

Panel PBA

Problem

N

N

Y

Y

LED

Ok?

1. Check the LED Signal from CPU on Main PBA

2. Check the Harness (Signal, VCC, GND)

3. Check the related Circuit, Pattern & Component
4. Replace the Panel PBA

N

Y

Near End

Ok?

End

1. Check the Near-End Sensor on Main PBA

2. Check the Harness

3. Check and Replace the Micro S/W

Sensor

Problem

N

Y

Paper End

Ok?

1. Check the Paper End Sensor Signal on Main PBA
2. Check the related Circuit, Pattern & Component

3. Check the Harness

4. Check and Replace the P_End Sensor

N

Y

Advertising