Server Properties Configuration

Manual Documentation Number: ESP904-0504

Chapter 5

33

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Server Serial Port (Select 1 to 4)

The configuration for each port is displayed one at a time. In the

ESP

Manager

, double-click on the port in the Serial Server List. This brings up

the Server Properties window for that port. Make any desired changes to the
configuration and then click on Update. Only the settings for the port shown
are stored.

N

N

o

o

t

t

e

e

:

:

Click Update to store settings for each port before changing to the other port.

Using

Telnet

or

Console Mode

, Save stores settings for all ports

simultaneously.

Baud Rate

The serial port baud rate on the ESP904 must match the serial baud rate of
the connected device unless using Virtual COM mode. In Virtual COM mode
the software program will establish serial settings.

Data/Parity/Stop

Set this to match the data format used by the device connected when the
Virtual COM mode is not being used.

Flow Control

The Flow Control setting must match the requirements of the device
connected.

N

N

o

o

t

t

e

e

:

:

Select None when setting ESP Port 1 as RS-485 or 4-wire RS-422.

Connection Mode

The Connection Mode field has three options:

Server

,

Client

and

Client (no

heartbeat)

When using the

Virtual COM Port

feature, select

Server.

When using a

TCP

or

UDP Socket

program, select

Server

.

When using

Paired Mode

communication between two serial servers set

up one as a

Client

and the other as a

Server

.

When connecting to a server that does not support

Heartbeat

, select

Client (no Heartbeat).

Server Properties Configuration

34

Chapter 5

Manual Documentation Number: ESP904-0504

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

TCP/UDP Protocol

Select TCP (Transmission Control Protocol) or UDP (User Datagram
Protocol) protocol. If the application does not require a UDP connection,
select TCP. TCP guarantees reliable communication with error checking
whereas UDP provides faster transmission.

TCP/UDP Port

This sets the port number for connection. The default port number is

4000

,

4001

,

4002

, and

4003

for serial ports 1, 2, 3, and 4 respectively.

In all modes of operation,

Direct IP

or

Virtual COM

, the port number set in

the ESP904 menu must match the

Virtual COM

or socket software port

settings.

N

N

o

o

t

t

e

e

:

:

Example: The Virtual COM default setting is TCP/UDP Port 4000. If the port #

property is changed to 4001, the virtual COM port will have to be changed to
4001. The hardware settings can be changed from the ESP Manager or

Console Configuration Menu. The Virtual COM port setting also can be
changed within the Device Manager of the computer on which it is installed.

Remote IP Address

This is a security feature activated by entering the IP address of the desired
client. The ESP904 will only communicate with the listed IP address and all
other requests for connection will be filtered out. The ESP904 must be set up
as a

TCP

or

UDP Server

to use this feature. The default setting is

255.255.255.255

.

If

Paired Mode

is not being used, do not change this setting until the

application has been tested and is communicating properly. Then activate the
address filtering feature.

N

N

o

o

t

t

e

e

:

:

Refer to Chapter 1 Paired Mode

Timeout

Default for the Timeout property is 0, or no timeout. Setting Timeout to any
value between 1 and 255 seconds activates it. If set to 5 seconds and the
ESP904 is configured as a Server. In this scenario the Client makes a
connection and communications start. If communications are ideal for 5
seconds the ESP904 will reset and make itself available for another client
connection.