Appendix c: rs-485 connections - 65 – B&B Electronics ESP904 User Manual

Page 38

Advertising
background image

RS-485

Connections

Manual Documentation Number: ESP904-0504

Appendix C

65

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

A

A

P

P

P

P

E

E

N

N

D

D

I

I

X

X

C

C

:

:

R

R

S

S

-

-

4

4

8

8

5

5

C

C

O

O

N

N

N

N

E

E

C

C

T

T

I

I

O

O

N

N

S

S

ESP904 DB-9 Pin-out in RS-485 Mode

RS-485

Signal Name

Direction RS-485 DB9M

Pin

Data B (+)

In/Out

DATA B (+)

3

Data A (−) In/Out

DATA

A

(−) 4

Signal Ground

---

GND

5

Figure 51. DB-9 Pin-out in RS-485 Mode

N

N

o

o

t

t

e

e

:

:

Some RS-485 devices are marked opposite the RS-485 standard, which

defines the Data B line as positive relative to Data A during a Mark state before

enabling the transmitter, and after transmitting before tri-stating. If an RS-485
device does not respond, try swapping the Data B and Data A lines.

Figure 52. 2-wire RS-485 Connection

RS-485

Connections

66

Appendix C

Manual Documentation Number: ESP904-0504

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

To connect 4-Wire RS-485 devices, the RS-422 Mode can be used provided
the ESP904 will be connected as a master in a single master system. If using
multiple masters, the ESP904 cannot be used, as it does not tri-state the
transmitter in RS-422 mode.