Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 32494

7

6

1

4

5

8

3

2

Figure E

Figure D

WARNING

Check for obstruc-

tions such as gas

lines, wires, exhaust,

etc. before drilling

or cutting. Failure to

do so may result in

serious bodily injury

and/or property

damage.

1. Drill two mounting holes

(holes 6 and 7).

2. Temporarily secure lift

using two mounting bolts

(holes 6 and 7).

3. Manually deploy lift and

check lift clearance. Drill

remaining mounting holes.

4. Install below floor mounting

hardware per instructions

supplied in kit.

5. Tighten mounting bolts per

sequence detailed above.

Note deflection detail below.

Mounting Bolt Torque

Target: 30 foot pounds.

2

Secure Lift

To Correct:

Dimensions

MUST

be Equal

90

90

To Correct:

®

298

23

®

298

23

®

298

23

LOOSEN

LOOSEN

TIGHTEN

LOOSEN

TIGHTEN

TIGHTEN

TIGHTEN

Loosen

Tighten

Tighten

Tighten

Loosen

Loosen

LOOSEN

Note. All fasteners must meet

FMVSS 571.403 Section 6.3.

Chassis

1. Drill 1-1/8" diameter

grommet access

hole. Check under

the vehicle for

obstructions.

2. Insert grommet.

Secure grommet

with two self-tap

screws.

3. Route ground

and power cables

through grommet.

Route cables clear

of exhaust, other

hot areas and

moving parts.

4. Connect ground

and power cables.

Ground Cable Corrosion:

When mounting ground

cables, remove undercoat-

ing, dirt, rust, etc. from

framing member around

mounting holes (minimum

5/8” diameter area). Ap-

ply protective coating to

mounting holes to prevent

corrosion. Failure to do

so will void warranty of

certain electrical compo-

nents.

Position and secure

ground cable clear

of lift operation.

CAUTION

Figure G

5/16"

External Tooth

Star Washer

5/16-18 x 3/4"

Thread Cutting

Screw

9/32" Diameter

Pilot Hole

Ground Cable Mounting

3

Attach Power and Ground Cables

Figure F

Ground Cables

Pump mounted ground

cable must be routed

and mounted directly to a

vehicle framing member.

Failure to do so will

void warranty of certain

electrical components.

Ground Cable

to Chassis

Battery Cable

to Circuit Sentry

Rubber

Boot

Star Washer

3/8" Hex Nut

Power

Feed Stud

Floor

Grommet