Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 32494

7

FMVSS 403/404 Certification Checklist

The outer barrier will not raise if occupied.

A warning will activate if the threshold area is

occupied when the platform is at least one inch

below floor level.

Lift platform movement shall be interrupted

unless the outer barrier is raised and the

outer barrier latch is positively engaged.

The following operations must be

functionally verified.

Vehicle movement is prevented unless the

lift door is closed, ensuring the lift is stowed.

Lift operation shall be prevented unless the

vehicle is stopped and vehicle movement is

prevented.

The platform will not fold/stow if occupied.

The inner roll stop will not raise if occupied.

DOT — Private Use Lift

DO

WN

OF

DL

UP

FN

U

OLD

Platform

Outboard

Platform

Inboard

Audible

Threshold

Warning

Inboard

Locator

Platform

Figure K

Threshold

Area

Lift Ready

Green LED

Outer Barrier

66

Platform Floor Level Adjustment

Platform Floor Level Position Adjustment:

1. Position platform at desired floor level position

(passenger loading/unloading height).

Note: Position platform such that:

a. the inner roll stop is laying flat on the threshold

plate

b. platforrm has not begun to fold

2. Turn Lift Power switch Off.

3. Press Floor Level Set button (located between

pump housing and lift tower).

4. While pressing the Floor Level Set button, turn the

Lift Power switch On.

5. Continue pressing the Floor Level Set button until

the lift sounds three “beeps.”

6. Release the Floor Level Set button.

7. Cycle lift to verify that platform stops at the set

floor level position.

Diagnostic codes have been established in event the

lift platform floor position does not set (the lift does not

sound three “beeps” - see Step 5 above). The control

board located inside the pump housing is equipped

with an LCD screen. Remove the pump cover to ac-

cess the LCD screen. The following diagnostic codes

will help resolve floor position setting problems:

91 – The platform position is out of a prede-

termined acceptable range

92 – The Bridge Microswitch is not activated

(adjust switch or lower the platform)

94 – The Outer Barrier Up switch is not

activated (adjust switch)

95 – The Outer Barrier Latched sensor is not

activated.

LCD Screen

Floor Level Set Button

Advertising