Lift operating instructions, Manual operating instructions – Braun 403 User Manual

Page 6

Advertising
background image

Braun Corporation FMVSS No. 403 Quick Reference Installation Sheet 32494

Lift Operating Instructions

T

R

Q

Manual Operating Instructions

If you experience power or equip-

ment failure, refer to the Manual

Operating Instructions to operate

the lift. Instructions and photos

are provided for all steps that

differ from standard lift operation

procedures. Manual Instructions

Decal 31894 (posted on pump

cover) provides manual operat-

ing instructions also. Refer to the

Release Valve

maximum

30 inch lbs

minimum

15 inch lbs

seats

(stops)

OP

EN

CL

O

SE

approximate

1/16” intervals

Valve Tightening

Specification:

Once valve seats

(stops), tighten 15

to 30 inch pounds

as shown.

Release Valve

Note: Close backup

pump release valve

securely before operating

electric pump.

A

C

B

To Unfold Platform (Out):

Using hand pump handle:

a. Place slotted end of pump handle onto

back-up pump release valve and turn

counterclockwise (open — 1/2 turn

only) until the platform reaches floor

level (fully unfolded). See Photo B.

b. Turn the release valve clockwise

(close) to stop the platform. See Photo

B.

Note: Valve must be tight, but do not

overtighten.

DOWN (To Lower Platform and Unfold

Outer Barrier):

Place slotted end of pump handle onto

back-up pump release valve and turn

counterclockwise (open — 1/2 turn only)

until the platform reaches ground level

and/or outer barrier unfolds. See Photo B.

UP (To Fold Outer Barrier and

Raise Platform):

Using hand pump handle:

a. Place slotted end of pump handle

onto back-up pump release valve

and turn clockwise to close secure-

ly. See Photo B.

Note: Valve must be tight, but do

not overtighten.

b. Insert handle into back-up pump and

stroke until platform reaches floor

level (see Photo C).

To Fold Platform (In):

Insert handle into back-up pump and

stroke until platform stops (folds fully).

See Photo C.

Note: Close back-up pump release

valve securely before operating elec-

tric pump.

S

U

Lift Operating Instructions for all

normal lift operation procedures

(such as loading and unloading

passengers). Follow all Lift

Operation Safety Precautions!

To Load Passenger (continued):

3. Unlock wheelchair brakes and load

passenger from platform into ve-

hicle. Note: Lower head to clear

door jamb header.

To Fold Platform (In):

Press FOLD (orange IN) switch

until platform stops (fully folded).

Release switch.

To Close Door(s):

Automatic Door Operator(s):

Press yellow CLOSE switch until

door(s) are fully closed. Release

switch.

Manual Door(s):

Manually close door(s) fully.

Open

(Down)

Close

(Up/Stop)

Advertising