Starting and ending panel installation – Mueller AP Panel User Manual

Page 19

Advertising
background image

19

STARTING AND ENDING PANEL INSTALLATION

Details are subject to change without prior notice.

Starting Panel

1. Apply adjustable strip as previously instructed.

2. Remove the overlap rib of the panel, making a straight cut the length of the panel.

3. Apply butyl tape continuously down the length of the adjustable strip, covering the wafer head screw.

4. Insert the cut edge of the panel into the strip, making sure the panel is seated fully into the strip.

5. Attach the panel to the roof with #9 x 1” woodgrip screws on the required centers.

NOTE: Alternate trim profiles are acceptable using the screw pattern shown.

Ending Panel

1. Remove the underlap rib of the panel at a point that is inside the adjustment portion

of the gable trim, making a straight cut the length of the panel (optimal 2” from gable edge).

2. Apply adjustable strip as previously instructed.

3. Test apply the panel to make sure that the cut edge seats fully into the strip.

4. Apply butyl tape and insert last panel into strip, making appropriate panel lap.

NOTE: Alternate trim profiles are acceptable using the screw pattern shown.

NOTE: To comply with Texas

Windstorm Certification Testing,

#12x11 SDT Type A screws must

be used in place of the #9

Woodgrip screws.

Advertising