Chimney installation, Chimney flashing - side flashing - vent – Mueller AP Panel User Manual

Page 28

Advertising
background image

28

CHIMNEY INSTALLATION

Details are subject to change without prior notice.

CHIMNEY FLASHING - SIDE

FLASHING - VENT

Procedures:
1. Trim the opening in the flashing to 20% smaller than

the pipe diameter.

2. Slide the flashing down over the pipe.

3. Seal between the flashing and the roofing with

tube caulk and set the flashing.

4. Form the flashing to fit the profile of the roof.

5. Fasten the flashing with woodgrip screws 1” on centers

NOTE: Alternate trim profiles are acceptable using the
screw pattern shown.

NOTE: In many cases it may be easier to locate
vent/pipe flashing in the flat area of the roof
panel (as shown) rather than have the penetration
occur at a panel rib. Determining panel layout
prior to installation often simplifies
flashing installation.

1. Trim and bend the right side flashing as indicated.
2. Trim the left side in a similar fashion.

NOTE: Alternate trim profiles are acceptable using the screw pattern shown.

NOTE: The left and right side flashing are mirror images of each other.

SIDE

SIDE

SIDE

Advertising