Hopper Testing

Plug in the Power Supply (34) and turn on the empty feeder
using the 2 Position Switch (32).

If the feeder doesn’t

turn on, refer to 12A on the next page for adjustment
procedure.

Turn off, then put approximately 100 bullets in the Feeder
Bowl (24).

Do not over fill.

Hold the Feed Tube (68) and turn on the Feeder using the
2 Position Switch (32). Catch the bullets as they fall and
make sure all bullets feed base-first. Adjustment the Wiper
Springs (27) and Bullet Guide Plate (11) if needed.

Cover the feed tube so the bullets fill to the switch lever,
causing the hopper to shut off.

If the hopper does not switch off, turn off the 2 Position
Switch (32), empty the feed tube, and refer to 12B on the
next page.

If the hopper shuts off, no adjustment necessary. Skip
step 12B on page 8.