J.P. Instruments EDM 760 Pilots Guide User Manual

Page 12

Advertising
background image

LeanFind Mode

Simply pre-lean, tap the LF button and begin leaning. The EDM-760
will assist you in finding the first cylinder to peak.

Buttons

Buttons, Front Panel
Two operating buttons control all functions of the EDM-760.

The term tap will be used to denote pressing a button momentarily. The
term hold will be used to denote pressing and holding a button for five
seconds or longer.

STEP Button

Located on the lower left side near the instrument face.

In the Automatic indexing mode, tapping the STEP button will

stop indexing and change to the Manual indexing mode. Then
each tap of the STEP button will display the next measurement
in the sequence.

In the LeanFind mode tapping the STEP button will terminate

the LeanFind mode and change to the Automatic indexing mode.

Secondary functions of the STEP button include:

In the Manual indexing mode holding the STEP button will

display the previous measurements in the sequence (rapidly
backwards).

In the programming procedures, described on page 37, tapping

the STEP button will advance to the next item in the list.

When an alarm is displayed (“Alarms” are described on page 43),

tapping the STEP button will temporarily delete that
measurement from the sequence for the next ten minutes.

When an alarm is displayed, holding the STEP button until the

word

OFF

appears will delete that measurement from the

sequence for the remainder of the flight.

Page 8

Engine Data Management

Advertising