Total

2. Total  the EDM-760 fuel used and  the actual fuel used for each

tank.

3. Record the current K factor here  left_________ right_________

and in the table below.

4. Calculate the New K Factor as follows:

New K Factor = ( 

EDM-760 fuel used)

x (

Current K factor)

(actual fuel used)

New K Factor (L) = ( 

(L)

)

x (

(L)

)

((L)

)

New K Factor (R )= ( 

(R)

)

x (

(R)

)

( (R)

)

Every time you fine tune the K factors, record the measurements here:

Date

EDM-

760 fuel

used

actual

fuel used

Current K

factor

Left

Right

New K factor

=

x

/

Left

Right

Fuel Flow Option Programming Procedure

Setting the K factor

This procedure is different than for setting other parameters. Place the
select switch in the FF position. If you haven’t already done so, start the
pilot programming procedure, simultaneously hold the STEP and LF
buttons for five seconds. You will see the word

PROGRAM for two

seconds.

1. Tap STEP button to advance to the screen

29.00=KF

LFT

For Your Safe Flight