Factory set default limits, Alarm limits – J.P. Instruments EDM 760 Pilots Guide User Manual

Page 47

Advertising
background image

Tap STEP

advances to

next item

Tap the LF

button to

sequence

Comments

TIME

2 500

Record time interval, in seconds

MNTH

I I2

Month

DAY

I 3I

Day

YEAR

00 99

Year (note: represents 1980 through 2079)

HOUR

OO 23

24 hour time. We suggest you set Zulu time

MIN

OO 59

This also zeros the seconds

N-----

N

I23456

Displays current Aircraft ID. To change Aircraft
ID, hold both STEP and LF buttons
simultaneously until the first character flashes.
Use LF to select the first character. STEP
moves to the next character. To Save the
Aircraft ID, Hold both STEP and LF for 5 sec.

END Y

Tap STEP button to exit the procedure.

Alarm Limits
Factory Set Default Limits

JPI conservatively sets the default alarm limits below Lycoming and
Continental recommendations.

Measuremen

t

Default Low

Limit

Default High Limit

Example

CHT

450°F 230°C

465

CHT

OIL

90°

F

32°C

230°F 110°C

280

OIL

TIT

1650°F 900°C

I720

TIT

CLD

-60°F/min. -33°C/min.

-65

CLD

DIF

500°F 280°C

525
DIF

BAT, 24 V

24V

32V

22 .4

BAT

BAT, 12 V

12V

16V

I7.6

BAT

LO FUEL

45 min

00.20

H.M

For Your Safe Flight