Changing the alarm limits, Procedure – J.P. Instruments EDM 760 Pilots Guide User Manual

Page 49

Advertising
background image

Changing the Alarm Limits Procedure

STEP button sequences to next item

LF button sequences through

these values

Description

FAC? N FAC? Y

Restore factory defaults?

REV X.XX

Firmware rev. number (momentary)

ENG F ENG C

EGT CHT EGT
CHT

Select F or C degrees for all engine temps.
You must also change the alarm limits to
°F or °C.

I6.0 H BAT

OR

30.5 H

BAT
( I0.0 H BAT 35.0 H

BAT )

Battery high voltage limit, set in 0.5 volt
increments.

I2.0 L BAT

OR

24.0 L

BAT
(8.5 L BAT 30.0 L

BAT)

Battery low voltage limit, set in 0.5 volt
increments.

500 DIF ( 30
DIF 990 DIF

)

EGT difference limit, set in 10° increments.

450 H CHT ( 90 H CHT

500 H )

CHT high limit, set in 5° increments.

-60 CLD ( -5 CLD 
-200 CLD )

Cooling limit, set in 5°/min. increments.

I650 TIT ( 650 TIT 
2000 TIT )

Also sets the maximum scale of the EGT
and TIT bar graph.

230 H OIL ( 40 H OIL 
500 H OIL )

Oil temperature high limit, set in 5°
increments.

90 L OIL ( I0 L OIL

250 L OIL )

Oil temperature low limit set in 5°
increments

TIT2 -N TIT2

-Y
FOR OIL FOR
OIL

If TIT2 probes are installed in place of oil
probes

CARB -N CARB

-Y
FOR T I T FOR

If carburetor probes are installed in place
of TIT probes

For Your Safe Flight