Infinity Connectors

5

© 2014 AEM Performance Electronics

Infinity Adapter Harness

The basis of the VW 1.8T Infinity kit is the adapter harness that mates the Infinity ECU with the cars factory wiring
harness. This adapter allows for seamless integration of the Infinity EMS onto your vehicle.

AEMNet is an open architecture based on CAN 2.0 which provides the ability for multiple enabled devices, such as
dashboards, data loggers, etc. to easily communicate with one another through two twisted cables (CAN+/CAN-).

The 2 pin Flash Enable connector is used as a secondary hardware flashing option by jumping the two wires
together using the included shunt connector. Note: Flashing will normally be performed in the software not using
this connector.

Integrated in the 1.8T adapter harness is an “auxiliary” connector. This is a Deutsch DTM 12P connector and is
used to adapt many common ancillary inputs and outputs easily. Included in the kit are a DTM 12P mating
connector, 12 DTM terminals, and a DTM 12P wedgelock. If used, these components will need to be terminated by
the installer or end user with 16-22awg wire (not included). Note: the pin numbering is based on the numbers
molded into the connector.

Deutsch

Pin

Infinity

Pin

Pin

Description

Default Pin

Function

Notes

1

C1-53

Analog 9

Fuel

Pressure

Can be used to monitor fuel pressure for fuel delivery calculation. Use AEM
stainless steel 100psig or 150psig sensor. Connect directly to signal w ire of
pressure sensor. See Setup Wizard. Analog input NOT reassignable.

2

C1-75

Analog 10

Baro

Can be used to monitor barometric pressure. Use AEM stainless steel MAP
sensor. Connect directly to signal w ire of MAP sensor. See Setup Wizard.
Analog input is also reassignable to other functions.

3

C1-74

Analog 11

Shift Sw itch

Can be used to activate Shift Cut for 'no-lift-shifting'. See Setup Wizard.
Analog input is also reassignable to other functions.

4

C1-73

Analog 13

Oil Pressure

Can be used to monitor oil pressure for Engine Protection. See Setup Wizard.
Analog input is also reassignable to other functions.

5

C1-40

Temp 3

Oil Temp

Can be used to monitor oil temperature. See Setup Wizard. Can also be used
to monitor other temp input.

Advertising