Input Function Assignments
Refer to pinout
Low Side Assignments
In the Wizard LowSide Assignment tab confirm the following settings:
Low Side 0: Fuel Pump
Frequency
= 30 Hz
Duty [%]
= See Table
LS0_Duty X-Axis
= Engine Speed [RPM]
LS0_Duty Y-Axis
= FuelPump
Low Side 2: Coolant Fan
Frequency
= 30 Hz
Duty [%]
= See Table
LS2_Duty X-Axis
= Engine Speed [RPM]
LS2_Duty Y-Axis
= CoolantFan1On
Low Side 5: Tacho
Frequency
= See Table
Duty [%]
= 50 %
LS5_Duty X-Axis
= Engine Speed [RPM]
LS5_Duty Y-Axis
= Any Selection
Low Side 6: IACV
Frequency
= 240 Hz
Duty [%]
= See Table
LS6_Duty X-Axis
= Engine Speed [RPM]
LS6_Duty Y-Axis
= Idle Position