Bunn JDF-2N User Manual

Page 22

Advertising
background image

22

38310 010406

TROUBLESHOOTING (cont.)

Check for "ON" position or no con-

tinuity - replace switch.

Clean or replace condenser filter.

Replace fan motor or check fan

blades for obstructions.

Check compressor relay coil for

120vac.

NOTE: Aleays check power with

coil attached.If no 120vac - replace

board. If yes, 120vac - replace

relay.

Note: Relay contacts normally

open.

Check compressor thermal overload

(N/C). If open check for dirty con-

denser filter or adequate ventilation

and space around machine.

Check refrigeration system for leaks

and proper charge.

See page 17 for instruction on how

to reset or change password.

Check all previous items that pre-

tain to refrigeration or cold water

recirculation

1. Compressor ON/OFF switch.

2. Dirty condenser filter or fins.

3. Condenser fan not running.

4. Compressor relay not activat-

ing.

5. Compressor not running.

6. Compressor running and not

cooling.

1. Dispenser lockout password

set.

1. Refrigeration or cold water recir-

culation system.

Refrigeration

All dispense stations not working

or all water & refill LED's flash and

beep 3 times.

Note: Cooling failure or excessive

bath and cabinet temperatures for

m ore than 4 hours will result in

touchpad lockout or no dispense.

Dispenser Locked Out

All dispense stations not working

or all water & refill LED's flash and

beep 3 times.

Hint: Display light goes out during

dispenser lockout feature, if the unit

has lighted graphics.

Cooling system failure or DBC

fault 3.

PROBLEM

PROBABLE CAUSE

REMEDY