Bunn JDF-2N User Manual

Page 26

Advertising
background image

26

38310 010406

TROUBLESHOOTING (cont.)

Unit is not working and no beep/light

fault codes

Difficulty brixing and/or weak bev-

erage

1. Step-down transformer.

2. Main control board.

1. Product viscosity or too cold.

2. Low water pressure.

3. High water pressure.

4. Dispense valve adjustment set-

ting.

5. Brix ratio.

Check for 120/24 vac. If no 24vac

reading, replace step-down trans-

former.

If 24 vac present and no red LED,

replace control board..

Hint: Red LED on main control board

is powered from the step-down

transformer 24 vac and rectified to

24 vdc by the rectifier.

Thorough thaw of product before

use (35° - 40°)

Maintain 20 psi or higher and a

minimum flow rate of 3 fl oz/sec.

Over 100 psi, install a pressure

regulator and set to 50 psi.

A) Perform 3 second water dispense

test. Factory setting is 1.0 oz/sec.

Acceptable water flow rate is .-0.8

to 1.5 oz/sec depending on the mix

ratio (4+1).

B) Adjust water to proper mix ratio.

Once water is set, adjust motor

speed (RPM) to achieve brix %.

Check for proper brix ratio per prod-

uct using Total Dispense method

and or refractometer method.

PROBLEM

PROBABLE CAUSE

REMEDY