TROUBLESHOOTING (cont.)

Dispense station not working "refill"

LED and beep code.

A) 3-Beep - Dispense/Rinse sens-

ing fault.

B) 4-Beep - Dispense/Rinse knob

mis-positioned.

Refill LED not extinguishing

All stations dispense concentrate

only

1. Bottle adapter switch mem-

brane

A) Dispense/Rinse switch mem-

brane shorted out simultaneously.

B) Dispense/Rinse switch mem-

brane open simultaneously.

2. Concentrate lockout (Dipswitch

#2) feature activated - locks out

station when refill light is ON.

3. Dispense touchpad.

Bottle adapter refill

Main water supply

Internal ON/OFF water valve

Frozen bath

Check for moisture at 3-pin con-

nector and clean. Apply electrical

insulating compound or replace

defective switch membrane.

Check knob for mis-position or re-

place defective switch membrane.

Check for proper orientation of

the Dispense/Rinse membrane

switch.

Hint: Good bottle adapter switch

membrane will sound the beeper

when you rotate the knob between

dispense and rinse to indicate closed

position.

Refill product or turn OFF concen-

trate lockout feature (Dipswitch

#2)

See Schematics and check corre-

sponding dispense station button

for continuity - replace touchpad.

Check wire terminals going to the

probes for proper connection or

refill probes need to be cleaned

and rinsed.

NOTE: Door switch resets the "Refill"

LEDs.

Check for ON position.

Check for ON position.

A) Compressor relay/contacts

shorted - replace relay.

B) Recirculating pump - replace or

check for kinked flex line.

PROBLEM

PROBABLE CAUSE

REMEDY