6. INSTALL WOOD MOUNTING STRIP

Measure and mark a level line on wall above cooktop location for the wood
mounting strip (see illustration beside and under step 2). Remove wood mounting
strip from back of hood.
Use #10 - 2’’ flat head screws to secure the mounting strip to the drywall. Make
sure to hit the wall studs.

CAUTION

Due to the weight of this hood, ensure that the wood strip is
attached to all of the available studs (2 studs minimum for a 30’’
width hood, more as hood width increases); not into the drywall
alone.

HD0174A

1. Drywall
2. Wood mounting strip
3. Flat head screw

4. Wall anchor location
5. Back of hood outline
6. Wall studs

4. REMOVE THE FILTERS AND THE GREASE DRIP RAIL(S)

A. Remove tape on filters.

Remove filters from hood and set aside.
NOTE: It is recommended to start with the
central one.

B. Remove tape on grease drip rail (1).

Lift out grease drip rail and set aside.

NOTE: The 60-inch width hood has 2 grease drip

rails.

HD0175

5. REMOVE THE PAN

Using a Phillips no. 2 or Robertson no. 2 screwdriver, remove the screws retaining
the pan (shaded part on illustration beside) to the hood. Remove the pan and set
aside.

HD0176

R

ETAINING SCREWS LOCATION

7. INSTALL THE FLUE AND/OR THE FLAT TOP COVER

7.1 D

UCTED

I

NSTALLATION

: A) O

PTIONAL

D

ECORATIVE

F

LUE

AEWP S

ERIES

For a ducted installation, refer to the instructions sheet included with the optional decorative flue.

B) O

PTIONAL FLAT TOP COVER

ADPWP S

ERIES

For ducting through back of hood only, install on hood or on the Optional Decorative Flue AEWP Series.
Refer to the instructions sheet included with the optional flat top cover.

7.2 N

ON

-D

UCTED

I

NSTALLATION

: N

ON

-D

UCT

K

IT

F

LUE

ANKWP S

ERIES

Refer to the installation sheet included with the non-duct kit for details.
NOTE: The Optional Flat Top Cover ADPWP Series can be installed on the Non-Duct Kit Flue ANKWP Series. Refer to

the instructions included with the optional flat top cover.