11.INSTALL THE ROUGH-IN PLATE TO THE HOOD

(ALL INSTALLATIONS)

11.1 A

LL

I

NSTALLATIONS

:

Run power cable to installation location. Refer to the instructions included
with the selected blower/rough-in kit (sold separately) for details on
installing the rough-in plate. Install the rough-in plate so that the wiring
box is located on the right side as you are facing the hood.

11.2 D

UCTED

I

NSTALLATIONS ONLY

:

For ducting through back of hood, remove existing plate from inside back
of hood and attach it to inside top of hood to cover hole. Secure to threaded
studs with same (4) nuts.
For ducting through top of hood, existing plate remains in place on inside
back of hood.

Connect ducting to transition or rough-in plate as you are installing the
rough-in plate. Use duct tape to make all joints secure and air-tight.

HD0179

Model 423, 424, 427 453, or 454
Attach transition (if required) to blower rough-in plate.
Use metal duct tape to make all joints secure and air-tight.

NOTE:

Model P6 blower plate connects directly to 7’’ round ductwork without
a transition.

9. SELECT BLOWER OPTION

(EXTERIOR OR INTERIOR, DUCTED INSTALLATION)

INTERIOR BLOWER: Follow all subsequent steps of this manual.

EXTERIOR BLOWER: Refer to instructions packed with exterior blower and follow steps 11 and up of the present manual.

HO0086

10.INSTALL TRANSITION TO ROUGH-IN PLATE

(INTERIOR BLOWER, DUCTED INSTAL.)

8. INSTALL THE HOOD

Rest the top back cavity of the hood on the wood mounting strip.

Secure the hood to wood mounting strip with (4) screws #8 x 3/4” (for 30” and 36”
width hoods) or (6) screws (for 42” width and wider hoods) provided at locations
shown. Drill (2) 3/16’’ size holes into the drywall for wall anchors through the existing
holes in the inside hood back in the locations shown. Then, install the two wall
anchors with the remaining #8 x 3/4” screws and the (2) washers provided.

For a non-ducted installation, go to step 11,

Install the Rough-in Plate.

CAUTION

Hold the hood until it is completely secured to the wood
mounting strip.

HD0178

W

ALL ANCHORS LOCATION

B

ACK OF HOOD

(

INSIDE VIEW

)

T

OP OF HOOD

(

INSIDE VIEW

)

R

OUGH

-

IN PLATE

ON TOP OF HOOD

P

LATE ON BACK OF HOOD

L

OCKNUTS

L

OCKNUTS

M

OUNTING SCREWS LOCATION

12.CONNECT THE WIRING

(ALL INSTALLATIONS)

Remove wiring cover from rough-in plate and set aside.

Connect BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.

Reinstall wiring cover.

WARNING

Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all
applicable codes and standards. Before connecting wires, switch power off at service panel and lock
service disconnecting means to prevent power to be switched on accidentally.

!