Procedure:
Remove the carrying handle (held by 2 screws) • Dismount cutter blades / blade arms
(see 13.3.1) • pull the faulty boot from the cylinder body and place the new one properly,
i.e. that the carrying handle fi xing screws go easily through the corresponding holes in
the boot. Mount and tighten carrying handle.

13.3.4

Carrying handle (see cover page item 11)

Damaged carrying handles have to be replaced immediately.
Procedure:
Remove the handle (held by 2 screws) and change it against a new one • Change
screws and disks if necessary.

13.3.5

Labels

All damaged or illegible indentifi cation stickers (Safety instructions, type label a.s.o)
have to be replaced.
Procedure:
Remove damaged stickers and clean surface with acetone • Put on new stickers.

13.3.6

Quick couplers

Quick couplers on the hoses have to be replaced when
- external damage can be observed • the locking sleeve doesn´work any more • oil

spill occurs even when the coupling is properly connected.

Remark: Faulty couplers have to be changed completely against genuine LUKAS
spares, i.e. it is not permissible to make any repair work.
The retaining nut on the hoses has to be tightened with a torque of M

A

= 45 Nm.