Trouble

Check

Cause

Remedy

Hoses cannot be

Pressurized

Relieve pump

coupled

pressure

On actuating blades

Hoses correctly

Air in the hydraulic

Thoroughly vent

move slowly or by

connected power

system

pump unit: see 9.1.1

jerks

pack operating

No pressure build-up

Not enough oil in hand Refi ll oil and vent

or motor pump.

system (see opera

ting instruction

9.1.1)

Star grip doesn‘t return

Return spring is

Ask authorized

to middle position

damaged or return

dealer or LUKAS

when released

mechanism is dirty

themselves for

repair

Oil leakage out of

Untightness, eventually Replace hoses

hoses or hose fi ttings

damages

Surface of hydraulic

Contact with

Change hoses

hoses is dissolved

agressive fl uids

Blades spread up at

Torque of the center

For retightening,

tips to a gap of more

bolt nut is unsuffi sient

see 13.2.1

than 3 mm even if not
fully loaded

Leakages on the

Seal defective piston

Replacement of

piston rod

rod

seals by authorized

dealer or LUKAS

themselves