Chapter 10 – emergency operation, Emergency power system, Lower controls – Snorkel TB66J User Manual

Page 67: Upper controls, Caution

Advertising
background image

TB66J – 0083740

63

Figure 10.2 – Lower Controls

5. Hold the ground operation switch upward to the

on position while holding the engine/emergency

power switch downward to the emergency power

position.

6. Hold the appropriate function toggle switch in the

desired direction.

Upper Controls

For the upper controls to be operational:

• The battery disconnect switch must be in the on

position.

• The emergency stop button at the lower controls

must be in the on position.

• The start switch at the lower controls must be in the

on position.

• The control selector switch at the lower controls

must be in the upper control position.

Use the following procedure to operate the machine using

the emergency power system from the upper controls.

1. Pull the emergency stop button outward (refer to

Figure 10.3).

2. Turn the start switch on.

Chapter 10 – Emergency Operation

If the main hydraulic system fails, the aerial platform

may be lowered and stowed using the emergency

power system. The main boom may be lowered using

the emergency lowering knob. The machine may be

towed at slow speeds using the optional tow kit if the

drive system fails.

Refer to Emergency Power System, Emergency Lower-

ing, or Towing for the appropriate procedure.

Emergency Power System

The emergency power system can be used to operate

the machine from the lower or upper controls.

Caution

The emergency power system is for emergency low-

ering and stowing only. The length of time the pump

can be operated depends on the capacity of the bat-

tery. Do not use this system for normal operation.

Only use the emergency power system if the main power

system fails.

Lower Controls

Use the following procedure to operate the machine using

the emergency power system from the lower controls.

1. Place the battery disconnect switch in the on position

(refer to Figure 10.1).

Figure 10.1 – Battery Disconnect Switch

2. Place the key in the start switch (refer to Figure 10.2)

and turn the switch to the on position.

3. Pull the emergency stop button outward.

4. Place the control selector switch in the lower controls

position.

Battery Disconnect Switch

Emergency

Stop Button

Engine/Emergency

Power Switch

Ground Operation

Switch

Control Selector

Switch

Start Switch

Advertising