Safety interlock test, Battery maintenance, Emergency lowering – Snorkel UL40 User Manual

Page 3: After use each day

Advertising
background image

3

EMERGENCY LOWERING

If the platform should fail to lower, NEVER

climb down the mast.

Ask a person on the ground to open the Emer-

gency Lowering Valve to lower the platform.

Serial Number 15001 - 21690

This valve is located through a cutout in the power

unit cover on the left side of the mast (Figure 3).
1. Pull the knob out and turn

1

/

4

turn to open the

Emergency Lowering Valve.

2. To close the Emergency Lowering Valve, turn

the knob until it snaps back in.

Serial Number 21691 - Current

The Emergency Control Valve Knob is located at

the rear of the machine. (Figure 3).
1. Open the valve by pulling and holding the

knob.

2. To close the Emergency Lowering Valve,

release the knob.

Once the platform is fully lowered, be certain that the

Emergency Lowering Valve is closed again. The

platform will not elevate if the Emergency Lowering

Valve is open.
NOTE: Optional auxiliary platform lowering

circuit allows operator to lower platform when

power source is interrupted. A warning light on

chassis controls shines when batteries for auxil-

iary platform lowering circuit are low (Figure 3).

Batteries for warning light are located inside

chassis control box.

Safety Interlock Test

NEVER perform this test from the platform.

1. Properly install all four (4) outriggers and level

base.

2. Release the tension on one (1) outrigger by turn-

ing the screwjack counterclockwise, until the

indicator lamp is no longer lit.

3. While standing on the ground activate the control

panel to elevate the platform. Platform should

not elevate.

4. Re-level the base with all four (4) outriggers then

repeat step 2 with another outrigger.

5. Repeat steps 2 , 3 & 4 until all four (4) outriggers

have been tested.

DO NOT use a machine that elevates when the

tension has been released on an outrigger. Ma-

chine must be repaired before using.

Battery Maintenance

Hazard of explosive gas mixture. Keep

sparks, flame and smoking materials away

from battery.
Always wear safety glasses when working

with batteries.
Battery fluid is highly corrosive. Rinse

away any spilled fluid thoroughly with

clean water.
Always replace battery with UpRight battery

or manufacturer approved replacement

weighing at least 52 lbs. (23.6 kg) each.
Check battery fluid level daily, especially if

work platform is being used in a warm, dry

climate.

If electrolyte level is less than

3

/

8

in. (10 mm) above

plates add distilled water only. DO NOT use tap

water with high mineral content, it will shorten

battery life.
Keep terminals and tops of batteries clean.
Refer to the Service Manual to extend battery life

and for complete service instructions.

AFTER USE EACH DAY

1. Ensure that the platform is fully lowered.
2. Park the machine on level ground, preferably

under cover.

3. Secure against vandals, children or unautho-

rized operation by turning the Key Switch to

OFF and remove the key.

Figure 3: Emergency Lowering

S/N 15001 - 21690

S/N 21691 - current

Advertising
This manual is related to the following products: