Maintenance

Section

4-8

A38E Work Platform

4.7 Switch Adjustments

(Figure 4-7 & 4-8)

TILT SENSOR

Function: This limit switch is activated when the

internal sensor in the ‘Tilt Sensor’ is tilted

3

°

or more (factory set at this value). When the Tilt

Sensor activates the elevating and telescope extend

functions will be locked out and an audible warning

alarm will sound. It will activate if the Chassis tilts 3

°

in any direction.

4.7

BOOM REST LIMIT SWITCH

Function: This limit switch is activated when the

Elevating Assembly is fully stowed and

the upper boom is sitting in the boom rest. The Boom

Rest is located on the side of the First Post on the

A38E Work Platform. The high speed drive can only

be operated when this switch is activated. When the

boom leaves the boom rest the Normally Open con-

tacts of the limit switch open and power is cut to the

high speed drive function.

Location: The switch is located on the side of the

First

(see fig 4-8)

Post on the Boom Rest Weldment.

Adjustment:The switch should be activated when the

boom sits in the boom rest. The lever is

adjustable and should be adjusted so that the

switch’s activation/deactivation point occurs just as

Boom 2 leaves the Boom Rest. To adjust the switch

loosen the lever clamping nut and rotate the lever.

Tighten the lever clamping nut. The switch should

periodically be checked for freedom of movement and

be kept clean from dirt and other contaminants that

might affect its free movement.

Adjustment:

1.Place machine on firm level surface ±¼°.
2.Use the Inclinometer

(p/n 057281-000) to ensure front and rear of

Chassis is level ±¼°.

3.Attach a 1 meter length of single core wire

to the “Reset Port” shown in Fig 4-7.

4.Attach the other end of the Single core wire

to the a negitive terminal on a battery cell and

hold for 3-4 seconds until a green LED flashes

from under the head of the Tilt sensor.

5.Test the Sensor as described below before

using the machine.

1.Raise the platform approximately 2

)t

f

7

(

m

2.Support the elevating assembly (see “Sup-

porting Elevating Assembly” on

page Section 4-7).

3.Jack the machine to the side (Past 3 degrees)

and the tilt alarm should sound..

Test:

Location: The Tilt Sensor is fitted in the rear chassis

alcove and is a vital part of the electrical

equipment.