Maintenance, Calibration – Snorkel A38E-sn004500+ User Manual

Page 59

Advertising
background image

Maintenance

Section

4-29

A38E Work Platform

4.21

Storage of the dead load (tare)

and the limit value (alarm)

1. MRW LIMIT has been mounted and the

control cable is connected.

2. The supply voltage has been applied and

the system is switched on.

3. The platform is unloaded and it has been

ensured that the platform has no base

4. Remove the program connector’s dust

5. Connect the Teach in Handset.

6. After a check-up the “ T“ in the label of the

Teach in Handset flashes with a frequency

contact.

protection cap.

of 5Hz.

4.21 START UP / CALIBRATION OF

THE MOBA OVERLOAD CELL.

START UP

Error LED

Alarm LED
Interface Connector
Zero/Tare LED

Power LED

• If the "T" at the label of the Teach in Handset

does not flash but light up constantly, this may

indicate an error that does not allow teaching.

1. System alarm The right red LED at

the MRW

2. Motion The determined weight fluc

tuates too

LIMIT lights up! (check system)

much! (check platform)

7. After the key labeled with “4“ is pressed for 4

8. The platform has to be loaded with an alarm

weight (100%) and it has to be ensured that the

platform has no base contact. The Handset stays

connected! The “T“ in the label of theTeach in

Handset starts flashing with a low frequency of

approx.1Hz.

The load has to be at least 10kg above the tare

weight, otherwise the “T“ in the label of theTeach

in Handset will not start flashing!

9. The key labeled with “4“ is pressed again for 4

seconds until the “T” of the Teach inHandset

lights up contstantly.

seconds, the “T” of the Teach in Handset lights

up constantly. In older versions (before 2010),

the “T“ in the label of the Teach in Handset

subsequently starts flashing with a low frequency

of approx.1Hz.

10. Disconnect the Teach in Handset.

11. The alarm is activated.

12. Slightly release and after 4 seconds reload the

platform again to check up the switch point.

13. After the alarm weight has been unloaded, the

orange LED at the MRW has to be activated

(+/- 15kg dead load control).

14. Close the program connector with the dust

protection cap.

15. Stick label stored and test r with the dust

protection cap.

16. The programming process is completed.

CALIBRATION

1. MRW LIMIT has been mounted and the control

cable is connected.

2. The supply voltage has been applied and the system

has been switched on.

3. The platform is unloaded and it has been ensured

that the platform has no base contact.

If the orange LED (zero/tare) at the MRW is activated,

a calibration is not necessary, but if the LED is not

activated, please continue with point 4.

4. Remove the program connector’s dust protection cap.

5. Connect the Teach in Handset.

6. After the check-up the “T“ in the Teach in Handset’s

label flashes with a frequency of 5Hz.

• If the "T" at the label of the Teach in Handset does not flash

but light up constantly this may indicate an error that does

not allow teaching.

1. System alarm The right red LED at the MRW LIMIT

lights up! (check system)

2. Motion The determined weight fluctuates much!

(check platform)

7. The key labeled with “4“ is activated for 4 seconds,

the “T” of the Teach in Handset lights up constantly.

In older versions (before 2010) after lighting up

constantly, the “T“ in the label of the Teach in Handset

starts flashing with a low frequency of approx.1Hz.

8. Disconnect the Teach in Handset.

9. Now the orange LED [zero/tare] at the MRW has to

be activated (+/- 15kg dead load control).

10. If the orange LED (zero/tare) at the MRW is not

activated, please repeat point 5. – 9.

11. Close the program connector with the dust

protection cap.

12. Stick label „stored and tested“ over the program

connector (included in delivery).

13. The programming process is completed.

Advertising