Troubleshooting, 3 a38e work platform – Snorkel A38E-sn004500+ User Manual

Page 63

Advertising
background image

Troubleshooting

Section

5-3

A38E Work Platform

4. Tacho faulty.

Repair or replace.

Machine

1. The A38E is not

Lower the Elevating

will not

in the stowed

Assembly.

drive in

position.

high speed. 2. Faulty boom rest Test and replace switch if

switch.

necessary.

3. Loss of

Check continuity and repair

continuity along

if necessary .

boom rest switch
cable.

4. Machine is not

Drive to level ground.

level.

5. Tilt Sensor is

Adjust Tilt Sensor or

faulty.

replace.

Machine

1. Machine is not

Lower the Platform and

will not

level.

drive to level ground.

drive while

2. Tilt Sensor is

Adjust Tilt Sensor or

elevated.

faulty.

replace.

PROBLEM

PROBABLE CAUSE

REMEDY

PROBLEM

PROBABLE CAUSE

REMEDY

prime the brake

drive is selected. If no

lines.

current is being fed to this
coil then replace the cable
feeding the coil or replace
the P.C.B.

5. Drive Reduction

Replace gearbox and

Gearbox has

ensure proper oil level is

seized due to

maintained.

lack of oil.

6. Brake Valves out Adjust Brake Pressure

of adjustment.

Reduction Valve to 100 Bar.

7. Joystick

Check for voltage signal on

damaged or

pin 8 or 11 on the traction

faulty.

motor control unit when
forward or reverse is
selected using the joystick.

Cage

1. Air in cage

Reprime or bleed as

levelling is

levelling closed

required. See Section 4.19.

erratic or

circuit.

irregular

2. Cage damaged, Replace.

throughout

hole centres are

the lift cycle.

out of position.

3. Damaged

Remove and inspect

Overcentre

O-Rings and seals.

valves on master Replace if necessary.
/slave cylinders.

Machine

1. Faulty Steering

Replace if necessary.

will not

Switch on

steer.

Joystick.

2. Loose

Reconnect if necessary.

connection on
steer solenoid
valve V5.

3. Faulty steering

Test steering valve coil. If

valve coil.

proper voltage is present

(Fault code :

and coil is not magnetised

59 or 61)

-Replace.

4. Steering valve

Replace valve.

V5 stuck.

5. Mechanical

Replace damaged parts.

Damage.

Machine

1. Faulty drive

Test and replace if

drives in

switch.

necessary.

reverse but

2. Loose

Check continuity and cable

not forward.

connection or

connections. Repair or

continuity lost to

replace as necessary.

reverse
contactor coil.

3. Reverse

Check that coil is receiving

contactor coil

48v. If it is and contacts are

faulty.

not closing then replace
the contactor.

4. Tacho faulty.

Repair or replace.

Machine

1. Faulty drive

Test and replace if

drives

switch.

necessary.

forward but

2. Loose

Check continuity and cable

not in

connection or

connections. Repair or

reverse.

continuity lost to

replace as necessary.

forward
contactor coil.

3. Forward

Check that coil is receiving

contactor coil

48V. If it is and contacts are

faulty.

not closing then replace
the contactor.

5.1