Linear error compensation, Ii – 1 installation set u p – ACU-RITE VUE READOUTS User Manual

Page 57

Advertising
background image

VUE

43

II – 1 Installation Set

u

p

Linear Error Compensation

Linear error compensation can be applied, if the results of the
comparison with a reference standard show a linear deviation over the
whole measuring length. In this case the error can be compensated by
the calculation of a single correction factor.

To calculate the linear error compensation use this formula:

Correction factor LEC = ((S – M) / M) x 10

6

ppm with

Example:

If the length of the standard used is 500 mm, and the measured length
along the X-axis is 499.95, then the LEC for the X-axis is 100 parts per
million (ppm).

LEC = ((500 – 499.95) / 499.95) x 10

6

ppm = 100 ppm (rounded to

the nearest whole number).

8

Once determined, the encoder’s error information is entered
directly. Press the TYPE soft key to select LINEAR compensation.

8

Enter the compensation factor in parts per million (ppm) and press
the ENTER key.

S

measured length with reference standard

M

measured length with device at axis

Advertising