STEP 25

Turn off supply power before wiring ALL200RM light switch. Turn off light switch in square box. Wire

light switch with 230V wiring. The 230V light switch leg can not be used as motor feed. Keep light and

motor hots separate. One light hot is black and 12 gauge. The other is white and 12 gauge. If wired

properly, a dimmer may be used. See Diagram O.

Never wire the ALL200RM improperly. Make sure electricity is turned off when installing and/or

performing maintenance on the ALL200RM. Improper wiring and/or electricity could cause death,

personal injury, and/or property damage.

Aladdin 12 Gauge Light Hot

(White)

Aladdin 12 Gauge Light Hot

(Black)

House Hot Light

Switch Leg 230V

House Hot Light

Switch Leg 230V

Diagram O