Important: Always read and follow operating instructions.

• 9

Electrical Wiring — 940111 only

1.

Remove the cover on the round box by taking out

the two screws.

Electrical Box

2.

Insert the emergency stop cable through the

empty box connector until the outside jacket just enters

the round box, or is completely inside the connector.

Tighten the two connector screws.
3.

Loosen the two screws that are clamping the foot

switch cable enough to push the hood switch cable into

the box. Tighten the two connector screws.

4.

Remove the screw-on connector from the BLACK

wire of the foot switch and add the BLACK wire from

the hood switch.

Screw connector on tightly.
5.

Join the WHITE wires from all three switches

together with a screw-on connector.

6.

Connect the BLACK wire from the stop switch to

the jumper wire from the outlet using a screw-on con-

nector.

7.

Re-attach the round cover plate and gasket to the

box with the two screws.

Electrical Wiring Assembly

Hood Switch
Cable (Ref)

Box
Mounting
Tab

Stop Switch
Cable (Ref)

Box Mounting
Tab

Foot Switch

Hood
Switch

Relay

Receptacle

Stop

Switch

Power
Cord

Black

Black

Black

Black

Black

White

White

White

Green

Green Screw

Supplied with

Round Box

Ground Lug Detail

04" Round Outlet Box

Green Wire

White

White

Black

Advertising