safety Precautions

• Read the Installation Instruction and Maintenance

Owner’s Manual before installing.

• Follow all local codes for installation.
• To reduce the risk of electric shock, connect only to

a properly grounded, ground fault interrupter (GFI).

• Do not immerse the IonGen

System Control Panel in water.

iongen

system sPecifications

• Input Voltage: 120 Volts
• Input Frequency: 60 Hz
• Output Voltage: 12 V
• Output Current: 0.5A
• Plug-in Transformer: UL Listed, CSA Listed

Rainproof Class 2

• Flow Chamber: Injection Molded Plastic
• Probe Material: 99% Copper
• Capacity: Up to 25,000 gallon water features

installation for the

aquascaPe iongen

system

ImPOrtant: Before installing the IonGen

System

in existing water features it is recommended to

thoroughly clean the pond of as much algae and

debris as possible. This will maximize the ions’ effectiveness

and speed to achieve desired results. The more algae

and debris in the water feature, the longer it will take the

Aquascape IonGen

System to provide noticeable results.

1. Mount the IonGen

System Control Panel

Mount the IonGen

System Control Panel

in the desired location;

making sure the power

cord reaches the GFI

outlet and the IonGen

Probe cord reaches the

desired location of the

IonGen

Probe. A 25’

extension Cable with Quick Connects (sold separately) is

available, if needed. The IonGen

System Control Panel

is weather-resistant, but in order to maximize the lifespan

of your unit, we suggest mounting the panel above ground

in a location protected from the elements.

2. Install the Flow Chamber
The Flow Chamber for the IonGen

System can be located

in several areas within the water feature. The Flow Chamber

is most effective when plumbed directly into the water feature’s

recirculating system. The IonGen

Probe can also be installed

without the Flow Chamber by submerging it in a filter, such as

in a skimmer or Pondless

®

Waterfall filter. Follow the step-by-

step installation instructions for the method you select.

INSTALLATION OPTION A:

Flow Chamber Installed into Recirculating System
• Cut and insert the Flow

Chamber into the water

feature’s recirculating system.

The Flow Chamber should

be positioned after the water

feature’s pump, and in a

region of the plumbing line

that drains by gravity. This is

enables you to easily service

the IonGen

Probe and

allows for overwintering the

Flow Chamber and fittings.

It is recommended to use a

pre-filter, such as a skimmer,

prior to the Flow Chamber,

in order to remove solids

and debris that may interfere

with the IonGen

Probe. A

small valve box may be used

for easy access during maintenance.

• Select the fittings needed for the application. The PVC slip

fitting is designed to be used with Schd 40 PVC pipe (Rigid

or Flex) and PVC glue. The multi-hose adapter fitting is

designed to be used with kink-free pipe and hose clamps.