Operating instructions – Aquascape IonGen Generation G2 (95027) User Manual

Page 5

Advertising
background image

5

www.aquascapeinc.com |

CAN 1-866-766-3426 |

US 1-866-877-6637

n

o

to

ols requir

ed

!

a

u

cu

n o

util néce

ss

a

ir

e!

• Hand thread the selected

fitting into the Flow

Chamber. (Do not use tools

to install the fittings into

the Flow Chamber. Fittings

need to be hand-tight only.)

• Hand-tighten the IonGen

Probe collar into position.

INSTALLATION OPTION B:

IonGen

Probe Only, No Flow Chamber Installed

The IonGen

Probe can also be submerged in a filter with

a sufficient flow of water, such as in a skimmer or Pondless

®

Waterfall Vault. The IonGen

Probe must be completely

submerged, and have sufficient water flow, in order to function

properly. Failure to provide sufficient water flow across IonGen

Probe will affect the IonGen

System’s performance.

See troubleshooting table for more information.

oPerating instructions

• before using the IonGen

System, please note the following:

– If the total alkalinity of the water is less than 100 ppm, you’ll

need to increase the level of alkalinity. Do not operate the

IonGen

System on water features with fish if the alkalinity

levels are below 100 ppm.

– If the total alkalinity of the water is above 250 ppm you will

need to decrease the level of alkalinity. If alkalinity is more

than 250 ppm it can be typically reduced by conducting a

partial water change. Check to make sure your tap water is

within the target water parameters.

– Alkalinity (not hardness) can be determined using the KH/

Alkalinity Test Kit sold separately (part #96019). Alkalinity

levels outside of the recommended parameters will

significantly reduce and possibly eliminate the effectiveness

of the IonGen

System to control the algae.

See targeted

Water Parameters section for more information.

• If using a diameter pipe larger than the smaller hose tails,

cut off the hose tails not being used with a hack saw in

order to maximize the water flow through the plumbing.

• When using the barbed

Multi-Hose Fitting, use a

metal hose clamp to secure

pipe to fitting.

• When using PVC, glue pipe into Slip Fitting using PVC glue

(not included). Follow the glue manufacturer’s directions for

proper plumbing steps.

• Install the IonGen

Probe into the top of Flow Chamber.

• Insert IonGen

Probe

cord through the IonGen

Probe collar.

• Plug the connector from

the Control Panel into

the IonGen

Probe

fitting connector.

95029 IonGen G2 EPA Instructions 01-13.indd 5

1/24/13 11:38 AM

Advertising