General maintenance, Danger – Autoquip FREIGHTLIFT FLH User Manual

Page 86

Advertising
background image

86




POWER UNIT


A. “Vertical” Heavy Duty Power Unit – Models FLH-4 thru FLH-6

DANGER!

HIGH VOLTAGE!! Disconnect and/or lock out the electrical supply to the

power unit prior to any maintenance being performed per OSHA Lock-Out,
Tag-Out procedures.

1. The “vertical” unit utilizes a heavy duty 5 HP/208, 230, or 460 Volts/60 hertz/3 phase

motor coupled to a high-pressure positive displacement gear pump, and Autoquip
Corporation’s

patented Deltatrol valve assembly. It is also available with a 230

Volts/60 hertz/single-phase motor as an option.


2. The following should be referenced in connecting the standard heavy-duty motors to

power sources. Remember that heavy wire must be used all the way to the power
source.


Power Unit

208 Volts

230 Volts

460 Volts

Standard Three Phase

16 AMPS

15.2 AMPS

7.6 AMPS

Standard Single Phase

N/A

28 AMPS

N/A


NOTE:

All amperage draws shown are full-load amperages.


B. Contractor Remote Power Unit – Models FLH-1 thru FLH-3

DANGER

!



HIGH VOLTAGE!! Disconnect and/or lock out the electrical supply to the
power unit prior to any maintenance being performed per OSHA Lock-Out,
Tag-Out procedures.


1. The Contractor Power Unit utilizes a “Super-Torque” intermittent duty (one full lift

cycle per four minute period) 5 HP/208/230/460 Volts/60 hertz/3 phase motor driving
a high pressure positive displacement pump assembly with internal relief check and
dump valves.

GENERAL MAINTENANCE

Advertising