Mk-5005s troubleshooting – Barranca Diamond MK-5005S Block Saw User Manual

Page 35

Advertising
background image

35

MK-5005S

TRoUBlESHooTING

(F)

Locate Cooling Channels inside

Blade Guard

cooling Flow Stopped

(A)

Check Cooling Flow

Control Valve is open

(B)

Remove Transfer Tube from

Blade Guard

(C)

Place Water Pump in clean

water source and check for flow

(if no flow go to Step G)

“Rodding” Cooling Channels is performed by removing the Flow Control Valve and then inserting a small wire

rod through the cooling channel inlet, located on the underside of the Blade Guard. The Cooling Channels

should be “rodded” until each of the outlet ports are open and free of foreign debris.

NoTE:

(D)

Verify Cooling Valve operation

by removing the valve from the

Blade Guard

(E)

Attach the Cooling Valve to the

Transfer Tube to verify flow –

if no flow, replace valve

Movable cutting Table Does Not Move correctly

(A)

Check Guide Rails are clean

and check for Roller Wheel

damage

(B)

Verify ease and freedom of

movement