Calibration Program

First Sensitivity Calibration

This program needs to be run whenever the settings

appear to be out of tolerance or when the machine

requests self-calibration spontaneously by displaying

the message “Er1 CAL”.

Select a wheel of average size and weight, preferably

with a limited unbalance, and mount it on the shaft.

Enter the correct wheel dimensions for the wheel.

Press

or

until the

CAL pro-

gram LED lights up.

Press

to confirm your choice.

The machine is now ready to carry out first sensitivity

calibration and displays the message “CA.1”.

• Rotate the wheel until the center indicator light

flashes and when the value ”100” (or 3.5 if ounce

mode is selected) is on the display.

Attach a 100 g (or 3.5 oz) sample weight to the OUT-

SIDE of the wheel rim. Position it at top-dead-center

(12 o’clock) exactly.

• Lower hood and press

to spin wheel.

With the wheel stopped, remove the sample weight

from the outside plane and rotate the wheel until

the center indicator light flashes and when the value

“100”(or 3.5) is on the display.

Attach the 100 g (or 3.5 oz) sample weight once

again to the OUTSIDE of the wheel rim. Position it at

top-dead-center at 12 o’clock exactly.

• Lower hood and press

to spin wheel.

When the calibration program is completed success-

fully, it is confirmed by a beep following the spin. If not,

the message “Er3 CAL” is displayed.

The self-calibration program ends with the display

showing out of balance values for the wheel (ignoring

the sample weight).

Remember: Remove the 100 g (3.5 oz) sample weight

at the end of the procedure.

Note: The

can be pressed at any given moment

to abort the calibration procedure and return to the pro-

gram selected previously.

Note: The calibration described above is valid for any

type of wheel.

Second Sensitivity Calibration

This program is used to self-calibrate the machine to

make it extremely accurate even with very high out of

balance values (over 200 g of static unbalance with aver-

age size wheels). It should be done when the machine

itself calls for it by displaying the message “Er2 CAL”.

Select a wheel of average size and weight, preferably

with a limited unbalance, and mount it on the shaft.

Enter the correct wheel dimensions for the wheel.

Press

or

until the

CAL pro-

gram LED lights up.

Press

twice to confirm your choice. The

machine is now ready to carry out second sensitiv-

ity calibration and will signal this with the message

“CA.2”.

Follow all the steps outlined above for first sensitivity

calibration.